The EDS-508A Layer 2 managed industrial Ethernet switch combines 6 x 10/100BaseT(X) RJ45 ports with 2 x single-mode 100BaseFX SC fibre ports reaching 80 km, making it well suited to long-haul links between remote plant, substation or roadside sites. Turbo Ring and Turbo Chain redundancy keep industrial networks resilient, and the metal IP30 housing handles an operating temperature range of -10 to 60°C.

Dual redundant 12/24/48 VDC power inputs with a relay alarm output support continuous operation, while IEEE 802.1X, RADIUS, TACACS+, SSH and HTTPS secure management access. EtherNet/IP and Modbus TCP support, DIN-rail mounting and ATEX and Class I Division 2 hazardous-location approvals make it a practical fit for factory automation, utilities and transport networks.

Features

- Turbo Ring and Turbo Chain redundancy with recovery time under 20 ms at 250 switches
- RSTP, STP and MSTP plus LACP link aggregation for resilient network topologies
- 80 km single-mode fibre uplinks for long-distance backhaul
- IEEE 802.1X, RADIUS, TACACS+, SSH and HTTPS security
- Dual redundant power inputs with relay alarm output
- EtherNet/IP and Modbus TCP industrial protocol support
- IGMP, VLAN and GVRP/GMRP support
- ATEX and Class I Division 2 hazardous-location approvals

Warranty

Moxa offers varying warranty periods depending on the product category:
• 5-Year Warranty: Applies to most industrial networking and connectivity products, including Ethernet switches, routers, wireless devices, serial converters, protocol gateways, and USB hubs.
• 3-Year Warranty: Covers x86-based industrial computers and panel PCs.
• 1-Year Warranty: Applies to external batteries, LCD panels, power adapters, antennas, and other select accessories.
Extended Warranty Options:
IP Trading offers tailored extended warranty solutions and support packages for Moxa products. Contact our team to explore options that align with your organization's needs.
https://www.moxa.com/en/support/repair-and-warranty/warranty-policy

All technical data should be verified on the manufacturer data sheets.

View full details

specs-tabs

Collapsible content

Technical Specifications

FAQs

Datasheet

Technical Specifications

- 6 x 10/100BaseT(X) RJ45 ports, auto negotiation, auto MDI/MDI-X
- 2 x 100BaseFX single-mode SC ports, 80 km typical distance, 1550 nm wavelength
- Optical power TX: 0 to -5 dBm; RX: -3 to -34 dBm; link budget 29 dB
- Layer 2 managed with 8 K MAC table, 64 VLANs (VID 1 to 4094) and 4 priority queues
- Packet buffer 1 Mbits, 256 IGMP groups
- Redundancy: STP, RSTP, MSTP, LACP, Turbo Ring v1/v2, Turbo Chain
- Security: HTTPS/SSL, SSH, RADIUS, TACACS+, Port Lock, IEEE 802.1X
- Management: SNMPv1/v2c/v3, LLDP, port mirroring, DHCP server/client, RMON, Syslog, Telnet, TFTP, DDM, IPv4/IPv6
- Industrial protocols: EtherNet/IP, Modbus TCP
- 2 alarm contact channels (relay output, 1 A @ 24 VDC) and 2 digital inputs
- Input voltage 12/24/48 VDC, redundant dual inputs; operating voltage 9.6 to 60 VDC
- Input current 0.30 A @ 24 VDC, with overload current and reverse polarity protection
- RS-232 console port (10-pin RJ45)
- Metal housing, IP30, 80.2 x 135 x 105 mm, 1040 g
- DIN-rail mounting; wall mounting with optional kit
- Operating temperature -10 to 60°C; storage -40 to 85°C; humidity 5 to 95% non-condensing
- Approvals: ATEX, Class I Division 2, DNV, UL 508, EN 62368-1, FCC Part 15B Class A
- MTBF 1,043,909 hrs (Telcordia/Bellcore, GB)

FAQs

Q: What fibre type does the EDS-508A-SS-SC-80 use?
A: It has 2 x 100BaseFX single-mode SC ports operating at 1550 nm over G.652 fibre, with a typical reach of 80 km and a 29 dB link budget.

Q: Is this a managed switch?
A: Yes. It is a Layer 2 managed switch supporting VLANs, SNMPv1/v2c/v3, RSTP/MSTP, LACP, port mirroring and IGMP.

Q: Does it support redundant power?
A: Yes. It has dual redundant 12/24/48 VDC inputs on removable terminal blocks, with overload current and reverse polarity protection, plus a relay alarm output for fault signalling.

Q: What redundancy protocols are supported?
A: Turbo Ring v1/v2 and Turbo Chain, as well as STP, RSTP, MSTP and LACP link aggregation. Turbo Ring recovery time is under 20 ms at 250 switches.

Q: What temperature range and housing does this model have?
A: This SKU is rated for -10 to 60°C operation in a metal IP30 housing for DIN-rail mounting. Wall mounting is possible with an optional kit.

Q: Does it support industrial automation protocols?
A: Yes. It supports EtherNet/IP and Modbus TCP, making it suitable for integration into factory automation and SCADA environments.

Datasheet

This product has a detailed PDF datasheet available. Open PDF datasheet in a new tab .

Your browser can’t display the embedded PDF. Click here to open it in a new tab.

Recently Viewed

  • Request for a Quote

    Looking for competitive pricing? Submit a request, and our team will provide a tailored quote that fits your needs.

  • Contact Us Directly

    Have a question or need immediate assistance? Call us for expert advice and real-time support.

    Call us Now  
  • Contact Us Directly

    Have a question or need immediate assistance? Call us for expert advice and real-time support.

    Contact us