The Moxa MGate MB3470-G2 is a 4-port advanced Modbus gateway that converts between Modbus RTU/ASCII serial devices and Modbus TCP networks. It provides four software-selectable RS-232/422/485 serial ports on DB9 male connectors and two 10/100 RJ45 Ethernet ports that can be configured for Ethernet cascade or dual-subnet operation. This standard temperature, non-isolated model operates from -10 to 60 C.

The gateway supports Modbus TCP client and server operation with up to 32 connections each in transparent mode, and handles function codes 1, 2, 3, 4, 5, 6, 15, 16 and 23. Management is available through a web console, Device Search Utility, MXview One and MXconfig, with HTTPS (TLS 1.2) and SNMPv3 for secure access. A 12 to 48 VDC input, IP30 metal housing and hazardous location approvals suit it to industrial control cabinets and DIN-rail installations.

Features

- Converts between Modbus RTU/ASCII and Modbus TCP
- Two Ethernet ports for cascade or dual-subnet operation
- Software-selectable RS-232/422/485 on each serial port
- Up to 32 Modbus TCP client and 32 server connections
- Automatic RS-485 data direction control (ADDC)
- Security functions including HTTPS (TLS 1.2) and SNMPv3
- ATEX, Class I Division 2 and IECEx hazardous location approvals

Warranty

Moxa offers varying warranty periods depending on the product category:
• 5-Year Warranty: Applies to most industrial networking and connectivity products, including Ethernet switches, routers, wireless devices, serial converters, protocol gateways, and USB hubs.
• 3-Year Warranty: Covers x86-based industrial computers and panel PCs.
• 1-Year Warranty: Applies to external batteries, LCD panels, power adapters, antennas, and other select accessories.
Extended Warranty Options:
IP Trading offers tailored extended warranty solutions and support packages for Moxa products. Contact our team to explore options that align with your organization's needs.
https://www.moxa.com/en/support/repair-and-warranty/warranty-policy

All technical data should be verified on the manufacturer data sheets.

View full details

specs-tabs

Collapsible content

Technical Specifications

FAQs

Datasheet

Technical Specifications

- 4 x RS-232/422/485 serial ports, software-selectable, DB9 male
- 2 x 10/100BaseT(X) RJ45 Ethernet ports, auto MDI/MDI-X, cascade or dual subnet
- 1.5 kV built-in magnetic isolation on Ethernet ports
- Serial bitrate: 50 bps to 921.6 kbps
- Modbus RTU/ASCII client and server (agent mode), Modbus TCP client and server
- Up to 32 client and 32 server connections (transparent mode)
- Supported function codes: 1, 2, 3, 4, 5, 6, 15, 16, 23
- Up to 128 commands per serial port, 600 tags, 4096 bytes total tag size
- Software-selectable RS-485 pull high/low resistors (1 kilo-ohm, 150 kilo-ohms) and 120 ohm terminator
- Input voltage: 12 to 48 VDC, 8-pin terminal block
- Relay contact rating: 1 A @ 30 VDC resistive load
- Operating temperature: -10 to 60 C, storage -40 to 85 C
- IP30 metal housing, 42 x 89 x 129 mm (without DIN-rail kit), 444 g
- Configuration: Web Console (HTTP/HTTPS), Device Search Utility, MCC Tool, MXview One, MXconfig
- Approvals include ATEX, Class I Division 2, IECEx and DNV maritime (24 VDC input)
- MTBF: 2,363,042 hrs (Telcordia SR-332)

FAQs

Q: What does the MGate MB3470-G2 do?
A: It is a Modbus gateway that bridges serial Modbus RTU/ASCII devices to Modbus TCP networks, allowing legacy serial equipment to communicate over Ethernet.

Q: Which serial interfaces does it support?
A: It has four DB9 male serial ports, each software-selectable between RS-232, RS-422 and RS-485, with baud rates from 50 bps to 921.6 kbps.

Q: What are the two Ethernet ports used for?
A: The two 10/100 RJ45 ports can be configured by software for Ethernet cascade (daisy-chaining) or for dual-subnet operation.

Q: What operating temperature range does this model support?
A: This standard temperature model operates from -10 to 60 C. It is a non-isolated variant.

Q: How is the gateway powered?
A: It accepts a 12 to 48 VDC input via an 8-pin terminal block. The DNV maritime certification applies with a 24 VDC power input.

Q: How many simultaneous Modbus TCP connections are supported?
A: In transparent mode it supports up to 32 client connections and up to 32 server connections.

Datasheet

This product has a detailed PDF datasheet available. Open PDF datasheet in a new tab .

Your browser can’t display the embedded PDF. Click here to open it in a new tab.

Recently Viewed

  • Request for a Quote

    Looking for competitive pricing? Submit a request, and our team will provide a tailored quote that fits your needs.

  • Contact Us Directly

    Have a question or need immediate assistance? Call us for expert advice and real-time support.

    Call us Now  
  • Contact Us Directly

    Have a question or need immediate assistance? Call us for expert advice and real-time support.

    Contact us