The ICF-1150 industrial serial-to-fibre converter transforms RS-232, RS-422 and RS-485 signals to multi-mode fibre over an SC connector, extending serial links up to a typical 5 km at 850 nm. This multi-mode SC model adds 2 kV isolation and IECEx hazardous-location certification, and is rated for operation from -40 to 85°C, suited to harsh industrial and hazardous-area deployments.

The converter features automatic data direction control (ADDC) for RS-485, baudrates from 50 bps to 921.6 kbps including non-standard rates, and a 12 to 48 VDC power input with overload current protection. Its IP30 metal housing mounts on a DIN rail, and it also carries ATEX Zone 2 and UL/cUL Class I Division 2 approvals for installation in classified environments.

Features

- Converts RS-232/422/485 serial signals to fibre to extend transmission distance
- 2 kV galvanic isolation protects equipment from ground loops and surges
- Hazardous-location certifications: IECEx, ATEX Zone 2 and UL/cUL Class I Div 2
- Wide -40 to 85°C operating temperature range for harsh environments
- Automatic data direction control (ADDC) simplifies RS-485 wiring
- Rugged IP30 metal housing with DIN-rail mounting
- Supports non-standard baudrates from 50 bps to 921.6 kbps

Warranty

Moxa offers varying warranty periods depending on the product category:
• 5-Year Warranty: Applies to most industrial networking and connectivity products, including Ethernet switches, routers, wireless devices, serial converters, protocol gateways, and USB hubs.
• 3-Year Warranty: Covers x86-based industrial computers and panel PCs.
• 1-Year Warranty: Applies to external batteries, LCD panels, power adapters, antennas, and other select accessories.
Extended Warranty Options:
IP Trading offers tailored extended warranty solutions and support packages for Moxa products. Contact our team to explore options that align with your organization's needs.
https://www.moxa.com/en/support/repair-and-warranty/warranty-policy

All technical data should be verified on the manufacturer data sheets.

View full details

specs-tabs

Collapsible content

Technical Specifications

FAQs

Datasheet

Technical Specifications

- 2 x serial ports supporting RS-232, RS-422 and RS-485
- Connectors: 5-pin terminal block and multi-mode SC fibre
- Baudrate: 50 bps to 921.6 kbps, supports non-standard baudrates
- Fibre type: multi-mode 50/125 µm or 62.5/125 µm
- Typical distance: 5 km at 850 nm
- Optical TX power: 0 to -8 dBm; RX power: 0 to -25 dBm
- Link budget: 15 dB, dispersion penalty 1 dB
- Isolation: 2 kV
- Input voltage: 12 to 48 VDC, 300 mA maximum, 1 power input
- Overload current protection supported
- Operating temperature: -40 to 85°C
- Humidity: 5 to 95% non-condensing
- Housing: metal, IP30
- Dimensions: 30.3 x 70 x 115 mm
- Weight: 330 g
- Installation: DIN-rail mounting
- Certifications: IECEx, ATEX Zone 2, UL/cUL Class I Division 2 Groups A/B/C/D
- MTBF: 792,085 hours

FAQs

Q: What serial interfaces does the ICF-1150I-M-SC-T-IEX support?
A: It converts RS-232, RS-422 and RS-485 serial signals to and from multi-mode fibre, with automatic data direction control (ADDC) for RS-485.

Q: What fibre type and distance does this model support?
A: It uses a multi-mode SC connector at 850 nm and supports 50/125 µm or 62.5/125 µm cable, with a typical distance of 5 km.

Q: Is this converter suitable for hazardous locations?
A: Yes. It carries IECEx, ATEX Zone 2 and UL/cUL Class I Division 2 Groups A/B/C/D certifications.

Q: What operating temperature range does it handle?
A: The -T variant operates from -40 to 85°C, making it suitable for extreme industrial environments.

Q: How is the converter powered and mounted?
A: It runs from a 12 to 48 VDC input via a terminal block with overload current protection, and mounts on a DIN rail in an IP30 metal housing.

Q: What does the 'I' in the model number indicate?
A: The I models include 2 kV isolation between the serial and power sides, protecting connected equipment.

Datasheet

This product has a detailed PDF datasheet available. Open PDF datasheet in a new tab .

Your browser can’t display the embedded PDF. Click here to open it in a new tab.

Recently Viewed

  • Request for a Quote

    Looking for competitive pricing? Submit a request, and our team will provide a tailored quote that fits your needs.

  • Contact Us Directly

    Have a question or need immediate assistance? Call us for expert advice and real-time support.

    Call us Now  
  • Contact Us Directly

    Have a question or need immediate assistance? Call us for expert advice and real-time support.

    Contact us