Skip to product information
1 of 1

Eaton

Eaton FLXTBA316C5 | FlexPDU G2 Basic 0U 3-Phase PDU, 16A, 36xC13 + 6xC19

Eaton FLXTBA316C5 | FlexPDU G2 Basic 0U 3-Phase PDU, 16A, 36xC13 + 6xC19

Authorised Eaton Partner

SKU:FLXTBA316C5

Stock Status: Enquire

$310.23 inc. GST
$282.03 ex. GST
Sale Stock Status: Enquire
Shipping calculated at checkout.

Description

The Eaton FlexPDU G2 Basic 0U vertical 3-phase rack PDU delivers 11.0 kW of nominal power through a 16A IEC 60309 input with a 3.0 m input cord. It provides 42 outlets in total, made up of 36 x C13 and 6 x C19, making it well suited to dense server and network racks that need a large number of IEC outlets in a compact footprint.

This Basic model is a non-metered, non-switched PDU, so it is a straightforward choice where power distribution is all that is required. The 0U vertical design preserves rack space, and the FlexPDU G2 family offers an upgrade path to Metered Input, Switched and Managed variants as monitoring needs grow.

Features

- Anti-ejection outlets help prevent accidental disconnection of connected equipment
- Compact 0U form factor maximises space at the rear of server racks
- Pure copper main circuit conductors
- Additional enclosure grounding points
- Operates in ambient temperatures up to 50 C
- Mounting button and mounting bracket included
- Optional environmental sensors and accessories available (FLXTTH, FLXTSEB, FLXTDORS and others)
- Upgrade path to Metered Input, Switched and Managed variants in the same family
- Customisation options available from Eaton engineering

Warranty

• Standard UPS (with VRLA batteries): 2–3 year warranty
• Lithium-ion UPS (up to 3kVA): 5-year warranty
Extended Warranty Options:
Extended Eaton UPS warranties are available through IP Trading. Contact us to discuss a plan that suits your power protection needs.
https://www.eaton.com/us/en-us/catalog/services/ups-services/understanding-your-eaton-ups-warranty-.html

All technical data should be verified on the manufacturer data sheets.

View full details

specs-tabs

Collapsible content

Technical Specifications

FAQs

Technical Specifications

- Form factor: 0U vertical
- Phase: 3-phase
- Input: IEC 60309 16A
- Nominal power: 11.0 kW
- Outlets: 36 x C13 + 6 x C19 (42 total)
- Input cable length: 3.0 m
- Technology: Basic
- Anti-ejection outlets: Yes
- Pure copper main circuit conductors: Yes
- Additional enclosure grounding points: Yes
- Maximum operating temperature: 50 C
- Operating altitude: 0-3000 m
- Warranty: 2 years

FAQs

Q: What input does the FLXTBA316C5 require?
A: It uses a 3-phase IEC 60309 16A input and is supplied with a 3.0 m input cord.

Q: How many outlets does this PDU provide?
A: It has 42 outlets in total, made up of 36 x C13 and 6 x C19.

Q: Does this model include metering or remote switching?
A: No. This is a Basic model, so it does not include metering or outlet switching and no network management module is fitted. Metered Input, Switched and Managed variants are available elsewhere in the FlexPDU G2 family.

Q: How is the PDU mounted in the rack?
A: It is a 0U vertical PDU and ships with a mounting button and mounting bracket, so it mounts alongside the equipment without using any rack units.

Q: What is the nominal power rating?
A: The nominal power rating is 11.0 kW.

Q: Can environmental sensors be added?
A: Yes. Optional environmental sensors and accessories from the FlexPDU G2 range, such as FLXTTH, FLXTSEB and FLXTDORS, are available.

Recently Viewed

  • Request for a Quote

    Looking for competitive pricing? Submit a request, and our team will provide a tailored quote that fits your needs.

  • Contact Us Directly

    Have a question or need immediate assistance? Call us for expert advice and real-time support.

    Call us Now  
  • Contact Us Directly

    Have a question or need immediate assistance? Call us for expert advice and real-time support.

    Contact us