Eaton FLXTBA116C2 | FlexPDU G2 Basic 0U 1-Phase PDU, 16A IEC 309, 20x C13 & 4x C19 Outlets

Eaton FLXTBA116C2 | FlexPDU G2 Basic 0U 1-Phase PDU, 16A IEC 309, 20x C13 & 4x C19 Outlets

SKU:FLXTBA116C2

Stock Status: Enquire

Regular price $273.16 AUD
Regular price
$273.16 AUD
$273.16 AUD
Regular price
Sale Stock Status: Enquire
Taxes included. Shipping calculated at checkout.

Description

The Eaton FlexPDU G2 BA is a 0U vertical basic Power Distribution Unit designed for high-density data centre and server rack deployments. Operating on a single-phase 16A IEC 309 input, it delivers reliable power distribution across 20 x IEC C13 and 4 x IEC C19 outlets, making it well-suited for powering mixed server, networking, and storage equipment in space-constrained rack environments. With a tool-free 0U vertical mounting form factor, the FlexPDU G2 BA maximises usable rack unit space while maintaining a clean and organised cable management layout. Eaton's FlexPDU G2 range is backed by manufacturer warranty and is engineered to meet the demanding uptime requirements of modern data centres. In stock and ready to ship from iptrading.com.au — order now for fast dispatch.

Features

- 0U vertical mounting preserves full rack unit capacity for active equipment
- 16A IEC 309 single-phase input — compatible with standard data centre power circuits
- 24 total outlets: 20 x C13 for standard devices, 4 x C19 for high-draw equipment
- Basic (BA) design provides simple, reliable power distribution with no unnecessary complexity
- Part of the Eaton FlexPDU G2 range — engineered for high-density data centre deployments
- Tool-free installation for quick and easy rack integration
- Eaton manufacturer warranty for peace of mind in mission-critical environments

Warranty

• Standard UPS (with VRLA batteries): 2–3 year warranty
• Lithium-ion UPS (up to 3kVA): 5-year warranty
Extended Warranty Options:
Extended Eaton UPS warranties are available through IP Trading. Contact us to discuss a plan that suits your power protection needs.
https://www.eaton.com/us/en-us/catalog/services/ups-services/understanding-your-eaton-ups-warranty-.html

All technical data should be verified on the manufacturer data sheets.

View full details

specs-tabs

Collapsible content

Technical Specifications

FAQs

Technical Specifications

- Form Factor: 0U Vertical (tool-free rack mount)
- Phase: 1-Phase
- Input Current: 16A
- Input Connector: IEC 309 (IEC 60309)
- Output Outlets: 20 x IEC C13, 4 x IEC C19
- Total Outlets: 24
- PDU Type: Basic (BA) — no metering or switching
- Mounting: Vertical 0U (does not consume rack units)
- Brand: Eaton
- Series: FlexPDU G2

FAQs

Q: What is the input connector type on the Eaton FLXTBA116C2?
A: The Eaton FlexPDU G2 BA uses an IEC 309 (IEC 60309) 16A single-phase input connector, which is a robust industrial-grade plug commonly found in data centre power feeds.

Q: How many outlets does this PDU provide?
A: It provides a total of 24 outlets — 20 x IEC C13 outlets (suitable for standard servers, switches, and 1U devices) and 4 x IEC C19 outlets (suitable for higher-draw equipment such as high-end servers and PDU-connected UPS systems).

Q: Does this PDU include power metering or outlet switching?
A: No. The 'BA' designation stands for Basic, meaning this PDU provides straightforward power distribution without built-in metering, monitoring, or individual outlet switching. For those features, consider Eaton's Metered or Switched FlexPDU G2 variants.

Q: What does '0U' mean and how does this PDU mount in a rack?
A: 0U means the PDU mounts vertically along the side of the rack cabinet and does not consume any rack unit (1U) space. This allows the full rack to remain available for active equipment.

Q: Is the Eaton FlexPDU G2 BA suitable for Australian data centre environments?
A: Yes. The IEC 309 input and standard IEC C13/C19 outlets are widely used in Australian data centres. The 16A single-phase rating is compatible with standard data centre power circuits.

Q: Can I purchase the Eaton FLXTBA116C2 in Australia from IP Trading?
A: Yes. The Eaton FLXTBA116C2 FlexPDU G2 BA is available through iptrading.com.au, an Australian B2B IT hardware specialist. It is in stock and ready for fast dispatch across Australia.

Recently Viewed

  • Request for a Quote

    Looking for competitive pricing? Submit a request, and our team will provide a tailored quote that fits your needs.

  • Contact Us Directly

    Have a question or need immediate assistance? Call us for expert advice and real-time support.

    Call us Now  
  • Contact Us Directly

    Have a question or need immediate assistance? Call us for expert advice and real-time support.

    Contact us