ATEN PE8324G3-AT | NRGence eco 24-Outlet Switched PDU, 32A IEC 60309, Zero-U, C13/C19

ATEN PE8324G3-AT | NRGence eco 24-Outlet Switched PDU, 32A IEC 60309, Zero-U, C13/C19

SKU:PE8324G3-AT

Stock Status: Enquire

Regular price $3,572.36 AUD
Regular price
$3,572.36 AUD
$3,572.36 AUD
Regular price
Sale Stock Status: Enquire
Taxes included. Shipping calculated at checkout.

Description

The ATEN PE8324G3 is an intelligent Zero-U rack PDU from the NRGence eco series, delivering outlet-level remote switching and real-time power metering across 24 AC outlets (21 x IEC320 C13 + 3 x IEC320 C19) via a 32A IEC 60309 input at 100–240 VAC. Designed for data centre and server room environments, it enables IT managers to remotely power on, off, or cycle individual outlets over TCP/IP, monitor per-outlet current, voltage, power, and watt-hour consumption, and configure automated on/off schedules — all from a browser-based interface or SNMP-capable management platform.

The PE8324G3 goes beyond basic switching with Proactive Overload Protection (POP), which automatically sheds the lowest-priority outlet to prevent circuit trips, and supports power-on sequencing to safely stage server boot sequences. Two 16A circuit breakers, 128-bit SSL encryption, 802.1x RADIUS authentication, and IP/MAC filtering ensure secure, enterprise-grade operation. External temperature and humidity sensor ports extend visibility to the physical environment, and full integration with ATEN NRGence eco DC software enables centralised multi-device energy and DCIM management. Order direct from iptrading.com.au — Australian-owned and operated since 2001.

Features

- Per-outlet remote power on/off/cycle control via TCP/IP from any browser or SNMP platform
- Real-time per-outlet metering of current, voltage, power, power dissipation, and watt-hour consumption
- Proactive Overload Protection (POP) — sheds lowest-priority outlet automatically to prevent circuit trips
- Configurable power-on sequencing with adjustable delay time per outlet for safe staged boot
- On/Off scheduling per outlet or outlet group — daily, weekly, or user-specified calendar events
- Wake on LAN, System After AC Back, and Kill the Power control modes supported
- External temperature and temperature/humidity sensor port for rack environment monitoring
- Native integration with ATEN NRGence eco DC for centralised multi-device energy and DCIM management
- Full SNMP V1/V2/V3 support for third-party NMS compatibility
- Intuitive browser-based GUI (Chrome, Firefox, Safari, IE) with no client software required
- Enterprise security: 128-bit SSL encryption, 802.1x RADIUS, IP/MAC address filtering, three-level account management
- Network-based firmware upgrades for easy maintenance
- Zero-U form factor mounts vertically on rack side to maximise usable rack unit space

Warranty

ATEN products sold by IP Trading are backed by a 24-month warranty against material defects and faulty workmanship from the date of shipment. Included accessories such as adapters and cables are covered for the same 24-month period, while batteries are covered by a 12-month warranty.

All technical data should be verified on the manufacturer data sheets.

View full details

specs-tabs

Collapsible content

Technical Specifications

FAQs

Technical Specifications

- Form Factor: Zero-U (0U) rack mount, side-mountable
- Total AC Outlets: 24 (21 x IEC320 C13 + 3 x IEC320 C19)
- Input Connection: IEC 60309 32A
- Nominal Input Voltage: 100–240 VAC
- Maximum Input Current: 32A
- Maximum Input Power: 7360 VA
- Input Frequency: 50–60 Hz
- Circuit Breakers: 2 x 16A
- Power Cord Length: 1.6 m
- Outlet Metering: Per-outlet — current, voltage, power, power dissipation, watt-hour
- Network Interface: 10/100 Mbps Ethernet (TCP/IP)
- Supported Protocols: TCP/IP, UDP, HTTP, HTTPS, SSL, SMTP, DHCP, ARP, NTP, DNS, Telnet, Ping, SNMP V1/V2/V3
- Security: 128-bit SSL, 802.1x RADIUS, IP/MAC filter, three-level account/password management
- Sensor Ports: Supports external temperature and temperature/humidity sensors

FAQs

Q: Can I control each outlet individually, or only the whole PDU at once?
A: Each of the 24 outlets can be independently switched on, off, or power-cycled remotely via TCP/IP. You can also group outlets and schedule on/off events daily, weekly, or at user-specified times — giving you granular control over every connected device.

Q: What is Proactive Overload Protection (POP) and how does it work?
A: POP automatically powers off the outlet with the lowest user-assigned priority when the PDU detects an overload condition, preventing a full circuit trip. You can pre-configure the shutdown priority for each outlet, so your most critical equipment remains powered while lower-priority loads are shed first.

Q: Is the PE8324G3 compatible with third-party SNMP management platforms?
A: Yes. The PE8324G3 supports SNMP V1, V2, and V3, making it compatible with most enterprise NMS and DCIM platforms. It also integrates natively with ATEN's NRGence eco DC software for centralised multi-PDU energy and infrastructure management.

Q: What distinguishes the G3 variant (PE8324G3) from other PE8324 models?
A: The G3 suffix denotes a specific inlet configuration: an IEC 60309 32A input plug operating at 100–240 VAC, with a 24-outlet mix of IEC320 C13 and C19 receptacles. Other regional variants may use different input plugs or voltage ranges, so confirm the G3 variant suits your Australian or international data centre power infrastructure.

Q: Does the PE8324G3 support environmental monitoring?
A: Yes. The PDU includes external sensor ports that support ATEN-compatible temperature sensors and combined temperature/humidity sensors, allowing you to monitor rack microclimate conditions alongside power data through the same browser-based or SNMP interface.

Q: Can I purchase the ATEN PE8324G3 in Australia through IP Trading?
A: Yes. The ATEN PE8324G3 is available to order directly from iptrading.com.au. IP Trading is an Australian-owned and operated IT hardware reseller, in business since 2001, supplying businesses, government, and data centre operators across Australia with genuine ATEN products.

Recently Viewed

  • Request for a Quote

    Looking for competitive pricing? Submit a request, and our team will provide a tailored quote that fits your needs.

  • Contact Us Directly

    Have a question or need immediate assistance? Call us for expert advice and real-time support.

    Call us Now  
  • Contact Us Directly

    Have a question or need immediate assistance? Call us for expert advice and real-time support.

    Contact us