APC APDU11550SW | NetShelter Switched 0U Rack PDU, 3-Phase 415V 100A, 36 Outlets

APC APDU11550SW | NetShelter Switched 0U Rack PDU, 3-Phase 415V 100A, 36 Outlets

SKU:APDU11550SW

Stock Status: Enquire

Regular price $0.00 AUD
Regular price
$0.00 AUD
$0.00 AUD
Regular price
Sale Stock Status: Enquire
Taxes included. Shipping calculated at checkout.

Description

The APC NetShelter Rack PDU Advanced 11000 Series APDU11550SW is a 0U, 3-phase switched power distribution unit delivering 415V / 100A (69.0 kVA) with 36 outlets — purpose-built for high-density Australian data centre and enterprise rack deployments. Remote outlet-level switching enables administrators to power cycle connected devices without physical access, while PDU-level metering at 1% accuracy provides billing-grade power visibility and overload alerting via Gigabit Ethernet network management.

A 4-in-1 combination outlet design (C13, C19, C15, or C21) offers unmatched flexibility across mixed server and networking loads, and the Live Swap Network Management Card allows NMC replacement without powering down the PDU or connected equipment. A second 10/100 Ethernet port supports PDU cascading, private network connectivity, or network redundancy — keeping management accessible even during AC power loss. Alternating phase outlet groupings with colour-coded labelling simplify load balancing and cable management in dense rack environments. Order now at iptrading.com.au — trusted by Australian IT professionals.

Features

- Remote per-outlet switching — power cycle individual connected devices from anywhere via network management interface
- PDU-level power metering at ±1% accuracy — supports billing-grade usage measurement and precise capacity planning
- 4-in-1 combination outlets accepting C13, C19, C15, or C21 plugs for maximum deployment flexibility
- Gigabit Ethernet primary management port for standardised, high-speed network connectivity
- Secondary 10/100 Ethernet port supports PDU cascading, dual-network connectivity, or management redundancy
- Live Swap Network Management Card — replace NMC without powering down the PDU or connected equipment
- Power Sharing across cascaded PDUs keeps NMC management accessible even during AC power loss
- Rated for operation up to 60°C (140°F) at full load — ideal for high-density and hot-aisle environments
- Alternating phase outlet groups with colour-coded and labelled breakers simplify load balancing
- Outlets arranged in alternating phase groups from top to bottom for improved power cord routing and management
- Local display for real-time power visibility and overload notification at the rack

Warranty

APC by Schneider Electric provides comprehensive warranty coverage for its UPS and power protection products. Warranty durations vary by product line and model:
• Back-UPS Series: Typically includes a 3-year warranty.
• Smart-UPS Series: Generally offers a 2 to 3-year warranty, depending on the specific model.
• SMT/SMX Models: Often come with a 3-year warranty on the UPS unit and a 2-year warranty on the battery.
Extended Warranty Options:
IP Trading offers extended warranty solutions for APC products, providing additional peace of mind beyond the standard warranty period. These extensions may include benefits such as:
• 24/7 technical support
• Free shipping on replacement parts
• Replacement of non-functioning batteries
For more details on extended warranty options and to tailor a solution to your needs, please contact the IP Trading team.

All technical data should be verified on the manufacturer data sheets.

View full details

specs-tabs

Collapsible content

Technical Specifications

FAQs

Technical Specifications

- Part Number: APDU11550SW
- Form Factor: 0U (Zero U) — mounts vertically in rack
- Phase: 3-Phase
- Input Voltage: 415V
- Input Current: 80A / 100A
- Power Rating: 69.0 kVA
- Number of Outlets: 36
- Inlet Connector: IEC 5125P6W
- Outlet Type: 4-in-1 combination (C13, C19, C15, or C21)
- Primary Network Port: Gigabit Ethernet
- Secondary Network Port: 10/100 Ethernet (cascade / redundancy)
- Metering Accuracy: ±1%
- Maximum Operating Temperature: 60°C (140°F) at full load
- Outlet Switching: Remote per-outlet on/off control

FAQs

Q: Can I buy the APC APDU11550SW in Australia?
A: Yes. The APDU11550SW is available now through iptrading.com.au, a trusted Australian B2B IT hardware reseller supplying data centre and enterprise infrastructure products to Australian businesses. Contact the team for pricing, availability, and volume enquiries.

Q: What does 'switched' mean on this Rack PDU?
A: A switched PDU allows you to remotely turn individual outlets on or off via the network management interface. This enables remote power cycling of hung servers or network devices without physical access to the rack — essential for unmanned data centres or remote branch deployments.

Q: What are the 4-in-1 combination outlets on the APDU11550SW?
A: Each outlet is a universal receptacle that accepts IEC C13, C19, C15, or C21 plugs. This eliminates the need to specify outlet types at order time and provides flexibility to connect a wide mix of servers, storage, and networking equipment with standard IEC power cords.

Q: Does this PDU support cascading multiple units from a single network connection?
A: Yes. The APDU11550SW includes a secondary 10/100 Ethernet port that allows multiple PDUs to be daisy-chained together and managed from a single IP address. This port can also connect the PDU to a second private network or provide network redundancy for high-availability environments.

Q: What is Live Swap NMC and why does it matter?
A: Live Swap allows the Network Management Card (NMC) to be removed and replaced while the PDU remains energised and connected devices continue to receive power. This minimises downtime during NMC upgrades or replacements and is critical in environments where any interruption to production systems is unacceptable.

Q: Is the APDU11550SW suitable for high-temperature data centre environments?
A: Yes. The unit is rated and approved to operate at up to 60°C (140°F) at full load, making it suitable for high-density, hot-aisle containment deployments where ambient rack temperatures are elevated.

Recently Viewed

  • Request for a Quote

    Looking for competitive pricing? Submit a request, and our team will provide a tailored quote that fits your needs.

  • Contact Us Directly

    Have a question or need immediate assistance? Call us for expert advice and real-time support.

    Call us Now  
  • Contact Us Directly

    Have a question or need immediate assistance? Call us for expert advice and real-time support.

    Contact us