Eaton FLXTMI332C3 | FlexPDU G2 Metered Input 0U 3-Phase 32A PDU, IEC 309 Inlet, 18x C13 & 6x C19 Outlets

Eaton FLXTMI332C3 | FlexPDU G2 Metered Input 0U 3-Phase 32A PDU, IEC 309 Inlet, 18x C13 & 6x C19 Outlets

SKU:FLXTMI332C3

Stock Status: Enquire

Regular price $963.39 AUD
Regular price
$963.39 AUD
$963.39 AUD
Regular price
Sale Stock Status: Enquire
Taxes included. Shipping calculated at checkout.

Description

The Eaton FlexPDU G2 Metered Input (MI) is a zero-U, 3-phase rack power distribution unit designed for demanding data centre and enterprise rack environments. Featuring a 32A IEC 309 (IEC 60309) inlet and 24 total outlets — 18 x IEC C13 and 6 x IEC C19 — it delivers high-density power distribution with metered input monitoring to give operations teams clear visibility of load consumption at the PDU level. Its slim 0U form factor mounts vertically in the rack, preserving valuable rack unit space for active equipment. The FlexPDU G2 MI series supports intelligent power management with input current metering, helping data centre operators stay within safe load thresholds and plan capacity effectively. The 3-phase design ensures balanced power distribution across connected loads, making it suitable for high-density server, storage, and networking deployments. Eaton's trusted build quality and global support network back this unit for long-term reliability. Visit iptrading.com.au to secure your order — enterprise-grade hardware with expert support.

Features

- Zero-U vertical form factor preserves all rack unit space for active equipment
- 3-phase 32A IEC 309 inlet for robust, high-capacity data centre power feeds
- 24 total outlets — 18 x C13 and 6 x C19 — supports mixed server and high-draw loads
- Metered Input monitoring provides real-time visibility of total PDU input current
- Helps prevent circuit overloads and supports proactive capacity planning
- Balanced 3-phase power distribution reduces per-phase load and improves efficiency
- Eaton FlexPDU G2 build quality designed for continuous 24/7 data centre operation

Warranty

• Standard UPS (with VRLA batteries): 2–3 year warranty
• Lithium-ion UPS (up to 3kVA): 5-year warranty
Extended Warranty Options:
Extended Eaton UPS warranties are available through IP Trading. Contact us to discuss a plan that suits your power protection needs.
https://www.eaton.com/us/en-us/catalog/services/ups-services/understanding-your-eaton-ups-warranty-.html

All technical data should be verified on the manufacturer data sheets.

View full details

specs-tabs

Collapsible content

Technical Specifications

FAQs

Technical Specifications

- Model: Eaton FlexPDU G2 Metered Input (MI)
- Form Factor: 0U (vertical rack mount)
- Phase: 3-Phase
- Input Current: 32A
- Input Connector: IEC 60309 (IEC 309) 3-phase plug
- Total Outlets: 24
- Outlet Types: 18 x IEC 60320 C13, 6 x IEC 60320 C19
- Monitoring: Metered Input — per-PDU input current monitoring
- Mounting: Zero-U vertical rack mounting
- Series: FlexPDU G2

FAQs

Q: What does 'Metered Input' (MI) mean on the Eaton FlexPDU G2?
A: Metered Input means the PDU monitors and displays the total input current draw at the PDU level. This allows data centre operators to track overall load consumption, avoid circuit overloads, and plan capacity without needing additional metering equipment.

Q: What type of input connection does the FLXTMI332C3 use?
A: It uses an IEC 60309 (commonly called IEC 309) 3-phase 32A inlet, which is a robust industrial-grade connector commonly found in data centres and server rooms with 3-phase power infrastructure.

Q: How many outlets does this PDU provide, and what types?
A: The PDU provides 24 outlets in total: 18 x IEC 60320 C13 outlets (suitable for standard server and networking equipment) and 6 x IEC 60320 C19 outlets (for higher-draw devices such as high-end servers, storage arrays, and GPUs).

Q: What does '0U' form factor mean and how does it mount in a rack?
A: 0U means the PDU occupies zero rack units of horizontal space. It is designed to mount vertically inside the rack — typically along a side rail — keeping all rack unit (1U–2U) slots available for active equipment, maximising rack density.

Q: Is the Eaton FlexPDU G2 suitable for high-density data centre deployments?
A: Yes. The 3-phase 32A input, combined with 24 mixed C13/C19 outlets and a 0U vertical form factor, makes it well suited to high-density rack deployments where space efficiency and balanced power distribution are critical.

Q: Can I purchase the Eaton FLXTMI332C3 in Australia through IP Trading?
A: Yes. IP Trading (iptrading.com.au) is an Australian B2B IT hardware specialist that supplies Eaton PDUs including the FlexPDU G2 range. Visit iptrading.com.au or contact the team directly for pricing, availability, and expert procurement support.

Recently Viewed

  • Request for a Quote

    Looking for competitive pricing? Submit a request, and our team will provide a tailored quote that fits your needs.

  • Contact Us Directly

    Have a question or need immediate assistance? Call us for expert advice and real-time support.

    Call us Now  
  • Contact Us Directly

    Have a question or need immediate assistance? Call us for expert advice and real-time support.

    Contact us