The MGate MB3170I-IEX is a 1-port Modbus TCP to Modbus RTU/ASCII gateway with 2 kV serial isolation and IECEx hazardous-location certification, 0 to 55°C. It bridges serial Modbus devices onto Ethernet networks and also supports Modbus serial master to serial slave communication, making it well suited to industrial automation, process control and Zone 2 hazardous-area deployments.

The software-selectable RS-232/422/485 serial port connects up to 31 Modbus RTU/ASCII slaves, while the gateway can connect to up to 32 Modbus TCP servers and be accessed by up to 32 Modbus TCP clients. Dual 10/100 Ethernet ports with built-in cascading simplify wiring, and redundant 12 to 48 VDC power inputs plus a relay output support reliable operation in the field.

Features

- Auto Device Routing for easy configuration
- Route by TCP port or IP address for flexible deployment
- Connects up to 32 Modbus TCP servers and up to 31 Modbus RTU/ASCII slaves
- Accessed by up to 32 Modbus TCP clients
- Supports Modbus serial master to serial slave communication
- Built-in Ethernet cascading for easy wiring
- Emergency request tunnels ensure QoS control
- Embedded Modbus traffic monitoring for easier troubleshooting
- Serial port with 2 kV isolation protection
- Redundant dual DC power inputs and 1 relay output
- Configuration via web console (HTTP/HTTPS), Device Search Utility, MGate Manager or Telnet

Warranty

Moxa offers varying warranty periods depending on the product category:
• 5-Year Warranty: Applies to most industrial networking and connectivity products, including Ethernet switches, routers, wireless devices, serial converters, protocol gateways, and USB hubs.
• 3-Year Warranty: Covers x86-based industrial computers and panel PCs.
• 1-Year Warranty: Applies to external batteries, LCD panels, power adapters, antennas, and other select accessories.
Extended Warranty Options:
IP Trading offers tailored extended warranty solutions and support packages for Moxa products. Contact our team to explore options that align with your organization's needs.
https://www.moxa.com/en/support/repair-and-warranty/warranty-policy

All technical data should be verified on the manufacturer data sheets.

View full details

specs-tabs

Collapsible content

Technical Specifications

FAQs

Technical Specifications

- 1 x RS-232/422/485 serial port, software selectable, 2 kV isolation
- Serial connector: DB9 male for RS-232, terminal block for RS-422/485
- Baudrate: 50 bps to 921.6 kbps
- 2 x 10/100BaseT(X) RJ45 Ethernet ports (1 IP, Ethernet cascade), Auto MDI/MDI-X
- 1.5 kV built-in magnetic isolation on Ethernet ports
- Modbus TCP Client (Master) and Server (Slave) to Modbus RTU/ASCII Master and Slave
- Up to 32 client connections and 32 server connections
- Input voltage: 12 to 48 VDC, redundant dual inputs via 7-pin terminal block
- Relay output: 1 A at 30 VDC resistive load
- Hazardous locations: IECEx, ATEX Zone 2, Class I Division 2
- Operating temperature: 0 to 55°C
- Storage temperature: -40 to 85°C
- Humidity: 5 to 95% non-condensing
- Plastic housing, IP30
- Dimensions (without ears): 29 x 89.2 x 118.5 mm
- Weight: 360 g

FAQs

Q: How many serial ports does the MGate MB3170I-IEX have?
A: It has 1 software-selectable RS-232/422/485 serial port with 2 kV isolation, using a DB9 male connector for RS-232 and a terminal block for RS-422/485.

Q: Is the MB3170I-IEX suitable for hazardous locations?
A: Yes. The -IEX model carries IECEx certification and is rated for ATEX Zone 2 and Class I Division 2 locations.

Q: What Modbus modes does it support?
A: It converts between Modbus TCP (Client and Server) and Modbus RTU/ASCII (Master and Slave), and also supports serial master to serial slave communication.

Q: How many devices can it connect to?
A: It can connect to up to 32 Modbus TCP servers and up to 31 Modbus RTU/ASCII slaves, and can be accessed by up to 32 Modbus TCP clients.

Q: What power input does it require?
A: It accepts 12 to 48 VDC through a 7-pin terminal block with redundant dual power inputs, and includes a relay output.

Q: How is the gateway configured?
A: Configuration is available through the web console (HTTP/HTTPS), Device Search Utility (DSU), MGate Manager or a Telnet console.

Recently Viewed

  • Request for a Quote

    Looking for competitive pricing? Submit a request, and our team will provide a tailored quote that fits your needs.

  • Contact Us Directly

    Have a question or need immediate assistance? Call us for expert advice and real-time support.

    Call us Now  
  • Contact Us Directly

    Have a question or need immediate assistance? Call us for expert advice and real-time support.

    Contact us